§ 30-123. Drainage design criteria.
Design Storm Event
The drainage systems for the following development categories, uses, and infrastructure categories shall be designated and evaluated for the following designated storm events:
Type Design Event
(min.)Retention/Detention
EventEvaluated
ForSite Drainage system and outfalls for commercial or multi-use subdivision 10-year storm 10-year storm
25-year storm100-year storm Drainage system and outfalls for residential subdivision 10-year storm 10-year storm
25-year storm100-year storm System Channel/system modification 10-year storm 25-year storm 25 and 100-year storms Collector street crossings 10-year storm N/A 25 and 100-year storms Arterial street crossings 25-year storm N/A 100-year storms Channel crossings in excess of 100 square feet 25-year storm N/A 25 and 100-year storms Relocated channel 100 year storm N/A 100 year storm For developments up to and including 2.5 acres
For developments larger than 2.5 acres
Channels shall not be incorporated into a storm water management facility
Or such lesser minimum design storm event as determined by the city.